Effects of wind on the dust and benzene-soluble matter captured by a small sampler
When dust is collected by means of filter holders for industrial hygiene measurements, quite low winds can cause serious errors which are often completely ignored. Collection efficiencies are presented for a filter-holder dust sampler now being used for dust measurements at British coke ovens. When the holder faces the wind, efficiency initially increases with particle size to above 100 per cent, but above about 15 μm efficiency falls. It probably increases again at larger particle sizes. Efficiency rapidly falls with increasing particle size when the holder is side-on to the wind.
Dust measurements were made in a dusty place on a coke oven, with one sampler facing, and another side-on to, a 2·6 m s−1 wind. The ratio of the concentrations measured by the two samplers was about 4 for total dust, but only about 1·5 for the benzene-soluble matter (BSM), suggesting that the BSM was concentrated on the smaller particles. These ratios are probably overestimates of the normal sampling errors. The errors are clearly important, however, although less so than with more open filter holders.
Publication Number: P/052
First Author: Ogden TL
Other Authors: Wood JD
Publisher: Oxford University Press,Oxford University, Oxford,Oxford
Download PublicationCOPYRIGHT ISSUES
Anyone wishing to make any commercial use of the downloadable articles on this page should contact the publishers of the journals. Please see the copyright notices on the journals' home pages:
- Annals of Occupational Hygiene
- Occupational and Environmental Medicine
- American Journal of Respiratory Cell and Molecular Biology
- QJM: An International Journal of Medicine
- Occupational Medicine
Permissions requests for Oxford Journals Online should be made to: [email protected]
Permissions requests for Occupational Health Review articles should be made to the editor at [email protected]